Research on improving the accuracy of total sulfur determination in highsulfur coal samples based on NDIR
-
作者
袁康何冰
-
Author
YUAN Kang;HE Bing
-
单位
长沙开元仪器有限公司国家能源集团河南电力有限公司
-
Organization
Changsha Kaiyuan Instruments Corporation Ltd.
State Energy Group Henan Electric Power Corporation Ltd.
-
摘要
非分光红外法(NDIR)以其快速、非接触、试剂污染少、高选择性和低检出限的优势而被广泛用于煤样全硫的测定,但由于样品中硫的释放特性不同导致二氧化硫检测器输出的吸收峰谱差异较大,因而在动态测定场合中采用积分面积法进行全硫测定时,峰谱变化对硫检测器动态检测性能的要求更高,尤其在高浓度测定时易出现吸收饱和、输出信号呈现严重的非线性从而影响全硫测定结果的精度。结合非分光红外检测原理,从高浓度测定时NDIR的响应角度剖析高硫煤样NDIR全硫测定的特点,提出气路缓冲、吸光度线性化2个NDIR全硫测定精度改善方法,以改善检测器响应区间及有效控制检测器的测定误差。吸光度线性化算法用于标样测试的应用验证结果表明:通过气路缓冲装置的气流均匀化效应可降低待测二氧化硫的浓度峰,使得NDIR检测器工作在合理的浓度范围;吸光度标定算法可将检测器的非线性响应线性化,能显著改善高硫样全硫测定精度。
-
Abstract
Non dispersive infrared (NDIR) method is widely used for the determination of total sulfur in coal sam⁃ples due to its advantages of fast, non⁃contact, low reagent pollution, high selectivity, and low detection limit.However, the different release characteristics of sulfur in the samples, the absorption peak spectrum output by thesulfur dioxide detector varies greatly. In dynamic measurement situation, the integral area method is used for totalsulfur measurement, and the peak spectrum changes have higher requirements for the dynamic detection performanceof the sulfur detector, especially in high concentration measurements, absorption saturation and severe nonlinearity ofthe output signal are prone to occur, which affects the accuracy of total sulfur measurement results. Based on theprinciple of NDIR, the characteristics of NDIR total sulfur determination in high sulfur coal samples are analyzed fromthe perspective of NDIR response during high concentration measurement to improve the detector response range andeffectively control the measurement error of the detector. Two methods for improving the accuracy of total sulfur deter⁃mination are proposed: gas buffering and absorbance linearization. The application validation results of the absor⁃bance linearization algorithm for standard sample testing indicate that the uniformity effect of the airflow through thegas buffer device can reduce the concentration peak of sulfur dioxide to be measured, that allowing the NDIR detectorto work in a reasonable concentration range; The absorbance calibration algorithm can linearize the nonlinear responseof the detector and significantly improve the accuracy of total sulfur determination in high sulfur samples.
-
关键词
非分光红外法全硫测定精度高硫煤样吸收峰谱气路缓冲吸光度标定线性化算法
-
KeyWords
non⁃dispersive infrared; total sulfur measurement accuracy; high sulfur coal sample; absorption peakspectrum; gas buffering; absorbance calibration; linearization algorithm
-
基金项目(Foundation)
国家重点研发计划专项资助项目(2018YFF01014000)
-
DOI
-
引用格式
袁康, 何冰. 基于非分光红外法的高硫煤样全硫测定精度改善研究 [J]. 煤质技术, 2023, 38 (3): 84-88.
-
Citation
YUAN Kang, HE Bing. Research on improving the accuracy of total sulfur determination in high sulfur coal samplesbased on NDIR [J]. Coal Quality Technology, 2023, 38 (3): 84-88.